|
||||
News and Information about the Test of Electronics in Research & Design, Production, Maintenance, and Installation. | ||||
Main MenuNewsletterNews AreaInfo AreaWeblinksProduct Focus |
Readers Top 5 News of last 30 days
News - Component Test
Automatic Fixture Removal Option for Network Analyzer14 July 2014 – Agilent announced a powerful new automatic fixture removal (AFR) option for its PNA Series network analyzers. Previously available only in Agilent’s Physical Layer Test System (PLTS) software, the error-correction technique offers a fast and easy way to accurately measure non-coaxial devices, saving engineers time and money. Many of today’s devices do not have coaxial connectors and are put in fixtures to measure them in a coaxial environment. However, accurate removal of the fixture’s effects is required to obtain a good measurement of the device-under-test. While EM simulation software modeling or multiple calibration standards fabricated on board can be used to characterize and remove a fixture, such approaches are complicated and time-consuming. Agilent’s new AFR option for the PNA provides engineers a faster, more accurate way to remove fixture effects from non-coaxial device measurements. A powerful five-step wizard quickly guides the engineer through the necessary steps. De-embed files can be saved in a variety of formats for later use in PNA, PLTS and Advanced Design System software. Using the AFR option, the engineer must first calibrate in coax with the reference planes at the inputs to the fixture. Then, one or more standards designed as a replica of the fixture’s 2-port thru or fixture half terminated with an open or short are measured. Even faster fixture de-embedding is possible with one-port AFR. In this case, the actual fixture is measured before the DUT is installed for the open standard. The AFR option then automatically characterizes and removes the fixture from the measurement. This one-port AFR capability is also now available in the PLTS software. “While the accuracy of our new AFR option is comparable to on-board TRL calibration, it is significantly easier to accomplish,” said Steve Scheppelmann, marketing manager of Agilent’s Component Test Division. “For microwave engineers new to AFR, that means they no longer have to perform complicated EM simulations or build on-board calibration kits to accurately correct for fixture effects. Signal integrity engineers already familiar with AFR will also benefit by saving even more time with the option’s one-port capability.” Agilent’s new AFR option (Option 007) for the PNA Series network analyzers is available now. Related Articles: |
Upcoming Events More events...
Tag CloudOscilloscope
JTAG
Boundary Scan
Goepel
PXI
Rohde & Schwarz
Tektronix
Keysight
AOI
Anritsu
National Instruments
Inspection
Teledyne LeCroy
Aeroflex
LTE
Yokogawa
AXI
Spectrum Analyzer
Keithley
In-Circuit-Test
Signal Analyzer
Automotive
EMC-Test
Signal Generator
Advantest
Multitest
B&K Precision
Corelis
Power Supply
SPI
Flying Prober
Teseq
Cognex
Switching
Teradyne
Viscom
Pickering
Fluke
GAO Tek
PCIe
|
||
© All about Test 2018 |